Tekmar 079 Slab Sensor Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Senzory Tekmar 079 Slab Sensor. tekmar 079 Slab Sensor User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 4
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
1 of 4 © 2007 D 079 - 05/07
D 079
Installation - Slab Sensor 079
STEP ONE
INSTALLING THE SENSOR
New Installations
Thin-Set or Thin-Pour Applications
If the floor covering is to be installed over either
a thin-set or thin-pour material of sufficient
depth, the 079 slab sensor can be placed
directly into either the thin-set material or the
thin-pour material and covered over. Ensure
that the sensor is located in such a position that
the attached wire is able to reach to a suitable
junction location. Splices within the thin-set or
(45 mm) long should be cut to accommodate the sensor. The sensor should be located
mid way between the heating elements to ensure a proper temperature reading.
Tiles
Thin-set
Electric
Cables
thin-pour should be avoided to ensure trouble free operation. The sensor should be located
mid way between the heating elements to ensure a proper temperature reading.
Thin Floor Coverings (less
than 3/8” (10 mm))
If a thin floor covering is to be installed directly
to the subfloor, a groove 1/8” (4 mm) wide by
1/16” (2 mm) deep can be cut into the surface of
the subfloor to accommodate the wire for the
sensor. Ensure that the sensor is located in
such a position that the attached wire is able
to reach to a suitable junction location. Splices
under the floor covering should be avoided to
ensure trouble free operation. A groove 3/16”
(5 mm) wide by 3/16” (5 mm) deep by 1-3/4”
Hardwood
Subfloor
SLAB SENSOR 079
The tekmar Slab Sensor 079 has a stainless steel sleeve which is designed for use in
concrete, thin-set or grout. The 079 is supplied with 10’ (3 m) of 2 conductor zipcord.
Hardwood
Subfloor
Thick Floor Coverings (great-
er than 3/8” (10 mm))
If a thick floor covering is to be installed directly
to the subfloor, a groove 1/8” (4 mm) wide by
1/16” (2 mm) deep can be cut into the back
of the flooring material to accommodate the
wire for the sensor. Ensure that the sensor is
located in such a position that the attached wire
is able to reach to a suitable junction location.
Zobrazit stránku 0
1 2 3 4

Shrnutí obsahu

Strany 1

1 of 4 © 2007 D 079 - 05/07D 079Installation - Slab Sensor 079STEP ONE INSTALLING THE SENSORNew InstallationsThin-Set or Thin-Pour Application

Strany 2 - Subfloor

© 2007 D 079 - 05/07 2 of 4 Splices under the floor covering should be avoided to ensure trouble free operation. A groove 3/16” (5 mm) wide by 3/1

Strany 3

3 of 4 © 2007 D 079 - 05/07Resistance TableSensor Testing InstructionsA good quality test meter capable of measuring up to 5,000 kΩ (1 kΩ = 100

Strany 4 - Technical Data

All specifications are subjectto change without notice4 of 4 D 079 - 05/07.tekmar Control Systems Ltd., Canadatekmar Control Systems, Inc., U.S.A.Head

Komentáře k této Příručce

Žádné komentáře