Copyright © D 369 -10/00
1 of 32
Output
Zone Valves or Zone Pumps
Input
Room
Temperatue
Unit (RTU)
Input
Room
Temperatue
Unit (RTU)
Input
Room
Temperatue
Unit (RTU)
Input
Room
Temperatue
Unit (RTU)
Input
Outdoor
Sensor
Included
Output
System
Pump
Input
115 V (ac)
Power
Supply
Input
Indoor
Sensor
Made in Canada by
tekmar Control Systems Ltd.
Power: 115 V 50/60 Hz 600 VA
Relays: 230 V (ac) 5 A
Signal wiring must be rated at least 300V.
H1202B
not testing
testing
testing paused
WARNING: Battery may explode
or cause burns if disassembled,
recharged or exposed to fire or
high temperatures.
Lithium Battery CR1620
POS (+) up
Press here
on battery to
remove it.
Menu
Item
Zone Control 369
Six Zones
C US
12345
Do not apply power
UnO
Sw
Zo
In
Zo
Out
Com
Out
20 21 22 23 24
Com
tN1
1
tN1
2
Indr
2
Com
25
tN1
3
26
tN1
4
27
Indr
4
28
Com
29
tN1/2
5
30
tN1
6
31
Indr
6
Do not apply power
Input
Remote
Display
Module
ItemMenu
WWSD
or
Output
Cooling
LR 58233
E150539
Input
tekmar Zone
Control
LR 58233
E150539
Output
tekmar Reset
Control
Input
Timer
INSTALLATION CATEGORY II
6
18
19
Power
16 17
10
Com
3-4
11
Zn
4
12
Zn
5
13
Com
5-6
14
Zn
6
15
Cooling
Sys
Pmp
NL
9
Zn
3
8
Zn
2
7
Com
1-2
Zn
1
View
°
F
!!!
ItemMenu
70
Input
Indoor
Sensor
OR OR
M
OR
M
OR
M
OR
M
OR
Input
Room
Temperatue
Unit (RTU)
ItemMenu
ItemMenu
ItemMenu
ItemMenu
M M
Input
Room
Temperatue
Unit (RTU)
ItemMenu
Input
Indoor
Sensor
70
Test
None
Setback
off
red
red
- Data Brochure
Zone Control 369
D 369
01/09
The Zone Control 369 is designed to control the temperature in up to six heating zones using Room Temperature Units (RTUs) or
indoor sensors. The 369 allows one stage heating zones, two stage heating zones, or a combination of one stage and two stage
heating zones. PID zoning logic allows for staggering and synchronization of multiple zones in order to minimize boiler short cycling.
The 369 is capable of operating a single cooling output and can provide automatic or manual heat / cool change over. When the 369
is used with a tekmar Reset or House Control, the 369 provides indoor temperature feedback that automatically adjusts the supply
water temperature in order to satisfy the zone with the highest heat load. A large Liquid Crystal Display (LCD) is incorporated in order
to view system status and operating information. The LCD and user key pad are used to set the control’s adjustments and to monitor
zone running times, outdoor high and low temperatures, minimum zone temperatures, and many other useful items.
Additional features include:
• Control Schedule • Slab Minimum and Slab Maximum Temperature Control
• Individual Zone Schedules • Remote Display and Adjustment Capabilities
• Optimum Start / Stop • Test Sequence to Ensure Proper Component Operation
• Cooling Control or Cooling Enable • 115 V (ac) Power Supply
• Manual Override • CE and CSA C US Certified (approved to applicable UL standards)
- 01/09
01/09
Zobrazit stránku 0
1 2 3 4 5 6 ... 31 32

Shrnutí obsahu

Strany 1 - - Data Brochure

Copyright © D 369 -10/001 of 32OutputZone Valves or Zone PumpsInputRoomTemperatueUnit (RTU)InputRoomTemperatueUnit (RTU)InputRoomTemperatueUnit (RTU)I

Strany 2 - User Interface

Copyright © D 369 -10/00 10 of 32SchdOvrUnOccItemMenuAdjustSchdOvrOccSchd12UnOSwZoInZoOut34ComTimer SwitchSCHEDULE OVERRIDES The 369 has a number of s

Strany 3 - Zone Adjust Menu

Copyright © D 369 -10/0011 of 3270ItemMenuUnOcc 1°FViewItemMenuUnOcc 1°FViewItemMenu°FViewSection D: tekmar Net 1/2 DevicesTEKMAR ROOM TEMPERATURE UNI

Strany 4 - Item Field

Copyright © D 369 -10/00 12 of 32InstallationCAUTIONImproper installation and operation of this control could result in damage to the equipment and po

Strany 5 - Section D

Copyright © D 369 -10/0013 of 3219PowerN18L115 V (ac)Cooling Unit1516Cooling191817PowerSysPmpLNLN115 V (ac)876Zn124 to 230 V (ac)Com1-2Zn2MOR45ComOutS

Strany 6 - Section A2: One Stage Heating

Copyright © D 369 -10/00 14 of 322829ComtN1/25ItemMenuOcc 1°FViewReset ControlCom10KPowerZoInZoOutComZone ControlFrom additionalzone controls23412UnOS

Strany 7 - Section B3

Copyright © D 369 -10/0015 of 32202122ComtN11ItemMenuUnOcc 1°FViewtN12ΩΩV45ComOutZone 6 (tN1 6 or Indr 6)Connect the Com terminal from the RTU to the

Strany 8 - Section B3: Cooling Control

Copyright © D 369 -10/00 16 of 32ΩVV103.5 to 126.5 V (ac)19PowerLN18115 V (ac)LNLPower1719NPmp18Sys24 to 230 V (ac)1-26Com Zn8217ZnMOR23451UnoSwZoInZo

Strany 9 - Section C: UnOccupied

Copyright © D 369 -10/0017 of 32NoneSetbackMiscCleaningThe control’s exterior can be cleaned using a damp cloth. Moisten cloth with water and wring ou

Strany 10 - UnOcc Ovr

Copyright © D 369 -10/00 18 of 32369 View Menu (1 of 1)Current outdoor air temperature as measured by the outdoorsensor. This is also the default disp

Strany 11 - 11 of 32

Copyright © D 369 -10/0019 of 32ActualSettingPUMP, VLV, THRMDefault = VLV SectionLTD INST ADVRangeAccessLevelDescriptionItem Field USERONE, TWODefault

Strany 12 - Installation

Copyright © D 369 -10/00 2 of 32MenuItemMenuItemMenuItemHow To Use The Data BrochureThis brochure is organized into four main sections. They are: 1) S

Strany 13 - Cooling Unit

Copyright © D 369 -10/00 20 of 32369 Monitor Menu (1 of 2)The highest recorded outdoor air temperature since this itemwas last cleared. This can be us

Strany 14 - UnOccupied Switch

Copyright © D 369 -10/0021 of 320 to 9999 hr0 to 9999 hr0 - 2550 - 255The total number of Zn 5 relay running hours since this itemwas last cleared.The

Strany 15 - Test The Sensors

Copyright © D 369 -10/00 22 of 32If the 7DAY/24h item is set to 7DAY, the schedule listed below for SATURDAY is also available for SUNDAY, MONDAY, TUE

Strany 16 - Zone Pump or Valve

Copyright © D 369 -10/0023 of 32Room Temperature Units (RTUs) 062 and 063 RTU 062 RTU 063369 RTU View Menu (1 of 1)Average temperature of all the zone

Strany 17 - Access Levels

Copyright © D 369 -10/00 24 of 32369 RTU Adjust Menu (1 of 1)The operating mode for this zone.RTU 1 to RTU 5 or RTU 6 if COOL MOD = NONE USEROFF, HEAT

Strany 18 - DescriptionItem Field

Copyright © D 369 -10/0025 of 32369 RTU Monitor Menu (1 of 1)The highest outdoor air temperature recorded sincethis item was last cleared. USER-67 to

Strany 19 - Section

Copyright © D 369 -10/00 26 of 32369 RTU Schd (Schedule) Menu (1 of 1) USERNONE, TMPY Occ Ovr,PERM Occ Ovr, TMPYUnOcc Ovr, PERMUnOcc Ovr, AWAY OvrDefa

Strany 20 - 369 Monitor Menu (1 of 2)

Copyright © D 369 -10/0027 of 32369 RTU Misc (Miscellaneous) Menu (1 of 1) USER°F, °CDefault = °FADV, INST, USER, LTDDefault = INSTOFF, 30 sec, ONDefa

Strany 21 - 369 Time Menu (1 of 1)

Copyright © D 369 -10/00 28 of 32Establish theProblemUnderstand theSequence ofOperationUse the TestRoutineSketch thePiping in theSystemDocument theCon

Strany 22

Copyright © D 369 -10/0029 of 32Error Displayed Description of Error369 Error Messages (1 of 3)The control was unable to store a piece of information

Strany 23

Copyright © D 369 -10/003 of 32AdjustAdjustZone1Monitor°FView°FTimeAMSchdMisc°FMENU FIELD The 369 has a number of menus used to monitor system status

Strany 24 - 369 RTU Adjust Menu (1 of 1)

Copyright © D 369 -10/00 30 of 32An incorrect device has been connected to the tekmar Net™ tN1 1 input terminal. Once the problemhas been corrected, p

Strany 25 - 369 RTU Time Menu (1 of 1)

Copyright © D 369 -10/0031 of 32The Remote 2 Sensor attached to RTU 1 is being read as an open circuit. RTU 1 will continue operationusing all remaini

Strany 26

Made in Canada bytekmar Control Systems Ltd.Power: 115 V 50/60 Hz 600 VARelays: 230 V (ac) 5 A Signal wiring must be rated at lea

Strany 27 - Testing the Control

Copyright © D 369 -10/00 4 of 32DisplayNumber FieldDisplays the current value ofthe selected itemButtonsSelects Menu, Itemsand adjusts settingsMenu Fi

Strany 28 - Use the Test

Copyright © D 369 -10/005 of 32Relay On Timeless heatRelay On Timemore heatCycle LengthRelay On TimeSequence of OperationSection AHeating OperationPag

Strany 29 - Voltages &

Copyright © D 369 -10/00 6 of 32AdjustZone12021ComtN11tN122223Indr2ItemMenuItemMenuView1°FUnOccView1°FUnOcc876Zn1CRCom1-2Zn2MMZONE CONTROL OPERATION W

Strany 30 - 369 Error Messages (2 of 3)

Copyright © D 369 -10/007 of 32AdjustZone2876Zn1CRCom1-2Zn2MMHi StageLo StageSection B1General CoolingSection B2Cooling EnableSection B3Cooling Contro

Strany 31 - 369 Error Messages (3 of 3)

Copyright © D 369 -10/00 8 of 32Cooling Unit1516CoolingCoolingThermostat2829ComtN1/25tN163031Indr6ItemMenuUnOcc 1°FViewCooling Unit1516CoolingDisplay

Strany 32 - Technical Data

Copyright © D 369 -10/009 of 32ItemMenuSchdAdjustZone2Zone 1Zone 2Zone 3Zone 4Setback Period 10 P.M. 12 A.M. 2 A.M. 4 A.M. 6 A.M.O